Server Technology
Network Cabinets & RacksSKU PRO4X Switched POPS PDU

Server Technology PRO4X Switched POPS PDU - Rack PDU

The Server Technology PRO4X Switched POPS PDU is a high-density power distribution unit designed for secure data center and network rack environments. It features the Xerus network interface for remote power management, detailed outlet monitoring, and granular on/off control. Procure.ae supplies this series of rack PDUs to businesses, schools, and government entities across the UAE and the wider Middle East and Africa region.

The PRO4X series provides comprehensive power distribution with 2-pole 20A breakers and a 10 kAIC interrupt rating. It supports HDOT Cx configurable outlets available in C13 or C19 types, secured by RamLock self-locking mechanisms. The Xerus platform enables remote access, PDU status monitoring, and branch current monitoring. Security features include configurable passwords, active directory support, and 256-bit AES encryption over SSH, SSL, and HTTPS protocols.

Environmental monitoring is achieved through integrated sensors for temperature, humidity, water, dry contact closure, airflow, and air pressure. The system alerts users via SNMP traps for immediate incident response. UL489 compliance ensures adherence to safety standards. Procure.ae offers bulk, project, and tender quotations for these units. Installation, free training, and ongoing support are available for all supplied equipment.

Type
Switched POPS PDU
  • Xerus Platform
  • Outlet Control
  • Security Standards
Price
On request · best price
1
Download spec sheet (PDF)
Delivery across UAE & GCCDubai, Abu Dhabi, Sharjah & beyond
Manufacturer warrantyBacked by the brand
InstallationArranged on request

Key features

01
Xerus Platform
Utilizes the Xerus network interface for remote power access and comprehensive device management.
02
Outlet Control
Enables precise outlet on/off control and branch current monitoring for individual power circuits.
03
Security Standards
Incorporates 256-bit AES encryption, active directory support, and secure login protocols.
04
Monitoring Sensors
Detects environmental conditions including temperature, humidity, water leaks, airflow, and air pressure.
05
Hardware Protection
Features 2-pole 20A breakers with a 10 kAIC interrupt rating for reliable circuit protection.
06
Configurable Outlets
Supports HDOT Cx configurable outlets available in C13 or C19 configurations with RamLock.

Specifications

10 specifications
General
Key FeaturesRamLock, HDOT Cx outlets, SNMP traps
ModelPRO4X Switched POPS PDU
TypeSwitched POPS PDU
Connectivity
Input Voltage208V, 230V, 400V, 415V
OutputsHDOT Cx (C13 or C19)
ProtocolsSNMP, SSH, SSL, HTTPS
Power
Power Capacity (VA)3.3kW, 5.0kW, 5.8kW, 7.3kW, 8.6kW, 10.0kW, 11.0kW, 11.5kW, 17.3kW, 23.0kW, 57.6kW, 86.6kW
Compliance
CertificationsUL489 Compliant
Security Featuresconfigurable password, active directory, 256-bit AES, SSH, SSL, HTTPS
Additional specifications
Part numbers in this rangeC4G24RD-4RBD2CAX, C4G24RD-5RBD2CAX, C4G36RA-0ABE2FE2, C4G36RA-2PBE2FE2, C4G36RA-2QBE2FE2, C4G36RA-DNBE2FE2, C4G36RA-DPBE2EE2, C4G36RA-DPBE2FE2, C4G36RA-DQBD2FE1, C4G36RA-ENBE2FE2, C4G36RA-EPBE2FE2, C4G36RA-EQBE2FE2, C4G36RA-GNBD2FE1, C4G36RA-GPBD2EE1, C4G36RA-GPBD2FE1, C4G36RA-U6BD2EE1, C4G36RA-U6BD2FE1, C4G36RA-YQBD2FE1, C4G36RC-GSBD2EAX, C4G36RC-GSBD2FAX, C4G48RA-0ABE2FD7, C4G48RA-2PBE2FD7, C4G48RA-2QBE2FD7, C4G48RA-DQBD2FD3, C4G48RA-ENBE2FD7, C4G48RA-EPBE2FD7, C4G48RA-EQBE2FD7, C4G48RA-GNBD2FD3, C4G48RA-GPBD2ED3, C4G48RA-GPBD2FD3, C4G48RA-U6BD2FD3, C4G48RA-YQBD2FD3

Questions

Can’t find your answer? Ask on WhatsApp

Does the PRO4X PDU support remote power management?
Yes, it uses the Xerus network interface for remote power access and outlet control. This allows administrators to monitor status and manage power distribution from anywhere.
What environmental sensors are included?
The unit monitors temperature, humidity, water leaks, dry contact closure, airflow, and air pressure. It sends alerts via SNMP traps when conditions change.
Is the PRO4X Switched POPS PDU UL489 compliant?
Yes, the device meets UL489 compliance standards. This ensures it adheres to recognized safety requirements for circuit breakers and power distribution equipment.
Can I buy the Server Technology PRO4X Switched POPS PDU in the UAE?
Request a quote via WhatsApp +971 4 546 5041 or email info@procure.ae.