Raritan PX4 Outlet Metered Switched Rack PDU

The Raritan PX4 Outlet Metered and Switched series provides precise power distribution for data centers. Featuring billing-grade ±0.5% metering, dual 10/100/1000 Ethernet ports, and hot-swappable controllers with a minimum 536MHz processor speed, these units support up to 36 outlets at 7.4 kVA capacity. Procure.ae supplies this series across the UAE.

These rack PDUs deliver high-precision power management with billing-grade ±0.5% metering for kW, kVA, V, A, harmonics, and power factor. Each unit features a hot-swappable controller with at least 16MB SPI Flash memory and 64MB DDR2 RAM, ensuring reliable operation. The system supports daisy chaining up to 32 PDUs via Ethernet or 16 via USB, allowing for scalable infrastructure deployment.

Remote monitoring is enabled through HTML, JSON-RPC, Redfish API, SSH, Telnet, MODBUS/TCP, and SNMPv3 protocols. The series includes dual 10/100/1000 Ethernet ports and supports environmental monitoring via up to 32 temp/humidity sensor functions. With mechanical outlet locking and 16A breakers rated at 10kAIC interrupting capacity, the PX4 ensures secure and stable power delivery for critical IT equipment.

Type
Rack PDU, metered and switched
  • Precision Metering
  • Hot-Swappable Controller
  • Advanced Connectivity
Price
On request · best price
1
Download spec sheet (PDF)
Delivery across UAE & GCCDubai, Abu Dhabi, Sharjah & beyond
Manufacturer warrantyBacked by the brand
InstallationArranged on request

Key features

01
Precision Metering
Billing-grade ±0.5% accuracy measures kW, kVA, V, A, harmonics, and power factor.
02
Hot-Swappable Controller
Embedded processor runs at minimum 536MHz with 16MB SPI Flash and 64MB DDR2 RAM.
03
Advanced Connectivity
Dual 10/100/1000 Ethernet ports support remote access via SNMPv3, Redfish API, and MODBUS/TCP.
04
Scalable Linking
Daisy chain up to 32 PDUs via Ethernet or 16 via USB with a shared GUI for up to eight units.
05
Power Security
Mechanical outlet locking and 16A breakers with 10kAIC interrupting capacity protect connected devices.

Specifications

11 specifications
General
ModelPX4 Outlet Metered and Switched
TypeRack PDU, metered and switched
Performance
ProcessorEmbedded processor, minimum 536MHz clock speed
RAM64MB DDR2 RAM
Storage16MB SPI Flash
Connectivity
ConnectivityDual 10/100/1000 Ethernet, Wi-Fi capable, USB
Input Voltage230V AC
ProtocolsHTML, JSON-RPC, Redfish API, SSH, Telnet, MODBUS/TCP, SNMPv3, TFTP, DHCP, MQTT
Power
Power Capacity (W)7400W (7.4 kVA)
Compliance
CertificationsCE
Additional specifications
Part numbers in this rangePX4-5057-E7, PX4-5057-E7M27, PX4-5057N-E7, PX4-5057U-E7, PX4-5161-E7, PX4-5161-E7M27, PX4-5161U-E7, PX4-51A0-E7M28V2, PX4-51A0-E7V2, PX4-5498R-E8, PX4-5528R-E8M28, PX4-5538-E7, PX4-5538-E7M28, PX4-560A-E8V2, PX4-561A-E8, PX4-5699-E7M28V2, PX4-5699-E7V2, PX4-5699N-E7M28V2, PX4-56A3-E7V2, PX4-5886X-E8, PX4-5917-E7V2, PX4-5917N-E7V2

Questions

Can’t find your answer? Ask on WhatsApp

Does the Raritan PX4 support remote monitoring?
Yes, it supports HTML, JSON-RPC, Redfish API, SSH, Telnet, MODBUS/TCP, and SNMPv3. This allows for comprehensive remote management of power parameters.
What is the metering accuracy?
The PX4 series offers billing-grade ±0.5% accuracy. It monitors kW, kVA, voltage, current, harmonics, and power factor for precise energy tracking.
Can I daisy chain multiple units?
Yes, you can connect up to 32 PDUs via Ethernet or 16 via USB. A shared GUI is available for managing up to eight linked devices simultaneously.
What are the controller specifications?
The controller is hot-swappable with a minimum 536MHz clock speed. It includes 16MB SPI Flash memory and 64MB DDR2 RAM for efficient data processing.
Can I buy the Raritan PX4 Outlet Metered Switched Rack PDU in the UAE?
Request a quote via WhatsApp +971 4 546 5041 or email info@procure.ae.

More in Network Cabinets & Racks

View all 10 types →