Raritan PX4 Outlet Metered and Switched Rack PDURaritan
Network Cabinets & RacksSKU PX4 Outlet Metered and Switched

Raritan PX4 Outlet Metered and Switched Rack PDU

The Raritan PX4 Outlet Metered and Switched series provides advanced power distribution for data centers. These rack PDUs feature billing-grade metering accuracy of ± 0.5% for kW, kVA, voltage, and current. Procure.ae supplies this series to businesses, schools, hospitals, and government buyers across the UAE and the wider Middle East & Africa (MEA). Installation and free training are available upon request.

This series delivers precise power management with an input rating of 7.4 kVA via an IEC 230V/32A 2P+PE inlet positioned at the bottom or angled. Each unit supports up to 36 outlets, configured as 18x C13 or 18x combined C13/C19, with a 16A breaker rating and 10kAIC interrupting capacity. Metering metrics include harmonic distortion, power factor, dip/swell detection, and neutral voltage monitoring. Remote monitoring is achieved via HTML, JSON-RPC, and Redfish API using SSH, Telnet, MODBUS/TCP, or SNMPv3 protocols.

The controller features a hot-swappable embedded processor with a minimum speed of 536MHz, 16MB SPI Flash, and 64MB DDR2 RAM. It supports cascade connections of up to 32 PDUs via Ethernet or 16 via USB, with up to 8 units linkable via Shared GUI. Environmental monitoring extends to temperature and humidity with support for 32 functions or 12 packages. Deployment options include TFTP, DHCP, SSH CLI, and USB flash, while data logging utilizes HTTP/S or MQTT.

Type
Rack PDU
  • Precision Metering
  • Power Capacity
  • Outlet Configuration
Price
On request · best price
1
Download spec sheet (PDF)
Delivery across UAE & GCCDubai, Abu Dhabi, Sharjah & beyond
Manufacturer warrantyBacked by the brand
InstallationArranged on request

Key features

01
Precision Metering
Billing-grade accuracy of ± 0.5% monitors kW, kVA, voltage, and current metrics.
02
Power Capacity
Supports 7.4 kVA input via IEC 230V/32A 2P+PE inlet with 16A breaker protection.
03
Outlet Configuration
Provides up to 36 outlets including 18x C13 or 18x combined C13/C19 types.
04
Remote Management
Enables monitoring via HTML, JSON-RPC, Redfish API, and protocols like SNMPv3.
05
Cascade Connectivity
Links up to 32 PDUs via Ethernet or 16 via USB for centralized control.
06
Environmental Monitoring
Tracks temperature and humidity with capacity for 32 functions or 12 packages.

Specifications

19 specifications
General
ModelPX4 Outlet Metered and Switched
TypeRack PDU
Performance
ProcessorEmbedded processor, min 536MHz
RAM64MB DDR2
Storage16MB SPI Flash
Connectivity
ConnectivityDual 10/100/1000 Ethernet, USB, Wi-Fi
EthernetDual 10/100/1000
Input Voltage230V
ProtocolsHTML, JSON-RPC, Redfish, SSH, Telnet, MODBUS/TCP, SNMPv3, HTTP/S, MQTT
Serial PortNo
Switching Capacity16A breakers, 10kAIC
USB PortsUSB for deployment and webcam
Wi-FiYes
Power
Power Capacity (VA)7.4 kVA
Physical
Operating HumidityEnvironmental monitoring capable
Operating TemperatureEnvironmental monitoring capable
Compliance
CertificationsCE
Security FeaturesMechanical outlet locking, 0V detection
Additional specifications
Part numbers in this rangePX4-5057-E7, PX4-5057-E7M27, PX4-5057N-E7, PX4-5057U-E7, PX4-5161-E7, PX4-5161-E7M27, PX4-5161U-E7, PX4-51A0-E7M28V2, PX4-51A0-E7V2, PX4-5498R-E8, PX4-5528R-E8M28, PX4-5538-E7, PX4-5538-E7M28, PX4-560A-E8V2, PX4-561A-E8, PX4-5699-E7M28V2, PX4-5699-E7V2, PX4-5699N-E7M28V2, PX4-56A3-E7V2, PX4-5886X-E8, PX4-5917-E7V2, PX4-5917N-E7V2

Questions

Can’t find your answer? Ask on WhatsApp

What is the metering accuracy of the Raritan PX4 series?
The series features billing-grade metering accuracy of ± 0.5% for power metrics including kW, kVA, voltage, and current. This ensures precise monitoring of power quality and usage for data center management.
How many outlets does the Raritan PX4 PDU support?
Each unit supports up to 36 outlets. Configurations include 18x C13 outlets or 18x combined C13/C19 outlets to accommodate various server and equipment connections.
Can the controller be replaced without powering down the system?
Yes, the controller is hot-swappable with an embedded processor. This allows for maintenance or upgrades without interrupting power distribution to connected devices.
What remote monitoring protocols are supported?
The PDU supports SSH, Telnet, MODBUS/TCP, and SNMPv3. It also offers remote monitoring via HTML, JSON-RPC, and Redfish API for comprehensive integration.
Can I buy the Raritan PX4 Outlet Metered and Switched PDU in the UAE?
Request a quote via WhatsApp +971 4 546 5041 or email info@procure.ae.