Raritan PX3 Inlet Metered 7.4kVA Vertical PDU - Rack PDU — specification sheet
Procure
Product specification sheet procure.ae · +971 4 546 5041
Raritan · PX3 Inlet Metered (PDU Metered) · Network Cabinets & Racks

Raritan PX3 Inlet Metered 7.4kVA Vertical PDU - Rack PDU

Raritan PX3 Inlet Metered 7.4kVA Vertical PDU - Rack PDU

The Raritan PX3 Inlet Metered is a 0U vertical monitored rack power distribution unit with 7.4kVA capacity and 41 outlets. It provides billing-grade metering per inlet and supports remote monitoring via SNMP and MODBUS. Procure.ae supplies this series across the UAE and wider MEA regions for enterprise data center and IT infrastructure needs.

This 0U vertical PDU delivers 7.4kVA power through 41 outlets, including one Schuko and forty C13 connectors. It features billing-grade metering with +/- 1% accuracy for kW, kVA, V, A, and Power Factor. The unit supports dual 10/100/1000 Ethernet ports, serial connectivity, and WiFi capability. It enables cascading up to 16 PDUs via Ethernet or USB for scalable power management.

Compatible with 230V, 400V, and 415V inputs, it handles currents from 16A to 125A depending on the model. The device monitors residual current and supports up to 32 environmental sensors. It operates at ambient temperatures up to 60°C at full load. Procure.ae offers bulk and project quotations for installation and support across the UAE.

Type
rack PDU

Key features

01
High Capacity Output
Provides 7.4kVA total power with 41 outlets, including one Schuko and forty C13 ports.
02
Billing-Grade Metering
Delivers +/- 1% accuracy for kW, kVA, voltage, current, and power factor per inlet.
03
Remote Monitoring
Supports SNMPv3, MODBUS/TCP, SSH, Telnet, and JSON-RPC protocols for network integration.
04
Scalable Architecture
Allows cascading up to 16 PDUs via Ethernet or USB for expanded power distribution.
05
Environmental Sensing
Supports connection of up to 32 external temperature and humidity sensors for monitoring.
06
Compact Form Factor
Features a 0U vertical design with dimensions of 70mm x 65mm x 1856mm for easy rack mounting.

Specifications

General
ModelPX3 Inlet Metered (PDU Metered)
Typerack PDU
Performance
Processorembedded, minimum 536MHz
RAM64MB DDR2
Storage16MB SPI Flash
Connectivity
Connectivitydual 10/100/1000 Ethernet, USB, WiFi
Ethernetdual 10/100/1000
Input Voltage230V, 400V, 415V
ProtocolsHTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, SNMPv3
Serial PortYes
USB PortsUSB for webcam and deployment
Wi-FiCapable
Power
Power Capacity (VA)7.4kVA
Physical
Dimensions70mm x 65mm x 1856mm
Operating Temperatureup to 60C
Additional specifications
Part numbers in this rangePX3-100AV-F12M11, PX3-1016V-V2, PX3-1032, PX3-1033V, PX3-1040U-V2, PX3-1045, PX3-1045V, PX3-1150-M18V2, PX3-1161V, PX3-1190R, PX3-1206R, PX3-1240-N1Q1V2, PX3-1260-N1, PX3-1260ER-E2, PX3-1266N-E2M5, PX3-1292-E2F10, PX3-1292R, PX3-1367T-E2H4M5N1, PX3-1390-N1Q1V2, PX3-1394U, PX3-1466R, PX3-1469R, PX3-1486-M11, PX3-1486V, PX3-1486V-M11, PX3-1488, PX3-1488CV, PX3-1488T, PX3-1488U, PX3-1488V, PX3-1493R-Q1, PX3-1493U, PX3-1493U-M11, PX3-1493V, PX3-1493V-M11, PX3-1528-M18P1V2, PX3-1528V-V2, PX3-158A-N1, PX3-1644-M11P1V3, PX3-1648V-M18, PX3-1648V-V4, PX3-1663-M11N1P1V3, PX3-1698X2-P1, PX3-1699U-E2N1, PX3-1699V-V2
QR code to Raritan PX3 Inlet Metered 7.4kVA Vertical PDU - Rack PDU on procure.ae
Get our best price for this product
Scan to open it on procure.ae, or contact the Procure sales team:
☎ +971 4 546 5041  ·  WhatsApp  ·  ✉ info@procure.ae  ·  🔗 View product page

This sheet is compiled from the product data held on procure.ae. For fully accurate and up-to-date figures, always refer to the manufacturer’s own specification sheet or datasheet for this model.

Specifications are provided by the manufacturer and may change without notice.